Three Phase (3PH) 3-Leg

REVO I 3PH – 3 Phase Unit to drive 3 phase load

REVO I 3PH


Technical Specification
  • Operating Temperature: 0-40°
  • Voltage Power Supply: 480V & 600V Max.
  • Auxiliary Power Supply: 110V / 220V / 415V AC
  • Fan Voltage supply: 230V ±15% as a standard and 110V on request
  • Analog Input 1: Primary reference - Current Input 0-20mA / 4-20mA - Voltage Input 0-10V - Potentiometer Input 10K Ohm min
  • Analog Input 2: External Current Limit, External feedback, alternate Setpoint
  • Digital Input: Two optoisolated digital input (12/24V DC), for Enable, SP AI1/ AI2, local / remote, heater bakeout, Alarm reset
  • Alarm Digital Output: Heater Break, Short circuit, Current Limit, SCR over temperature, watch dog, Relay Output
  • Firing: Soft Start + Phase Angle / Burst firing / Zero cross over
  • Soft Start Control: Digital adjustable ramp rate can be used
  • Control Feedback Mode: V/ V2/ I/ I2/ Vxl
  • Fuses: High speed Semiconductor fuses fitted Internally
  • Mounting: Panel mounting
  • Protection: IP20

REVO S 3PH Three phases static relay

REVO S 3PH


  • From 30 up to 800A
  • Voltage Range 480V, 600V and 690V
  • Load type: Resistance, IR Lamp long and medium waveform
  • Inputs: SSR Std, 0:10V, 4:20mA and Heather Break alarm are options
  • Firing mode: Zero Crossing, Burst Firing available with analogue input only

REVO C 3PH – Revo Connect Universal SCR Power Controller Three Phases

REVO C 3PH


  • Phases: 3
  • Current Range from 30 to 2100A.
  • Voltage Range 480V, 600V and 690V.
  • Inputs: 4:20mA, 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding
  • Firing mode: Burst Firing, Delayed Triggering and Phase Angle with or without Soft Start
  • Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
  • USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • 100 kA: Short Circuit Current Rating (SCCR) up to 600V
  • Approvals CE+EMC; EAC; cUL from 30A to 500A, UL from 600A to 2100A

Revo PN – Suitable to control Electric Heaters and IR Lamps in Industrial Heating Systems

REVO PN


  • Modules of 12 or 24 zones already divided into three phases or one phase from 4 to 24 zones
  • Logic input SSR 7÷30Vdc 9mA Max (ON ≥7Vdc OFF <6Vdc)
  • L1 - L2 - L3 Power Input 370 - 480V
  • Nominal current in continuous service Max 25A for each load
  • Max peak current (10ms) 700A
  • Nominal Voltage range Ue 24 - 600V
  • Isolation Voltage Ui 2500Vac

REVEX 3PH – The Power Controller On Demand

REVEX 3PH


Technical Specification
  • Load type: Normal Resistance, Infrared Short, Medium and Long Waveform
  • Inputs: 4:20mA, 0:10V, SSR and ModBus as std.
  • Firing mode: Burst Firing, Zero Crossing
  • Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
  • Communication: RS485 port. RTU Modbus® Protocol
  • USB: Port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • Approvals: Comply with CE+EMC / EAC
  • Dual Current Limit: For peak and RMS value
Option
  • All options are shown below with the relevant model code
  • HB Alarm to diagnose partial or Total Load Failure and Thyristor Short Circuit

CD3000S 3PH – From 15A to 90A

CD3000S 3PH


Technical Specification
  • Voltage power supply: 24V min, 480V Max, 600V on request
  • Input Signal: SSR (OFF state <1Vdc ON = 4÷30 Vdc) firing.
  • Firing: Zero crossing ZC.
  • Auxiliary Voltage Supply: 10Va power consumption.
  • Fan Voltage: 230V ± 15%.
  • Approvals:Comply with EMC; cULus available as an option.
  • Mounting: Din rail mounting up to 90A.
  • Operating Temperature: 0÷40° up to 90A included (for higher temperature see the derating curve)

Copyright © M/s Toshcon CD Automation Pvt. Ltd. H1 - 75 Gegal Industrial Area Ajmer - 305023 India T +91-145-2791112 | Any information you provide while visiting the www.cdautomation.in website will be used only by CD Automation company | CD Automation will not share your information with any other organisation, including its business partners, unless your explicitly agree. All Rights Reserved.